Finished stair rise and stringer cuts

Code numbers are finished numbers. Finished rise = rough rise − finish below + finish above, then the stringer drop, the bottom and top cuts, and headroom framed to 6 ft 10 in for a finished 6 ft 8 in.

Residential stairs · IRC R311.7 · 2021 IRC · assumes 1 in treads, ¾ in hardwood below, ¼ in vinyl above, ⅝ in drywall

Cut to framing: one stair, start to finish
StepFormulaThis stairCode
Finished riserough − finish below + finish above108½ − ¾ + ¼ = 108 inIRC R311.7.5.1 (risers are measured finished)
Layoutfinished rise ÷ risers15 risers at 7.2 inIRC R311.7.5.1 (≤ 7¾ in)
Stringer droptread − floor finish1 − ¾ = ¼ inkeeps the bottom riser within ⅜ in, IRC R311.7.5.1
Bottom cutriser − drop6.95 inIRC R311.7.5.1
Middle cutsriser7.2 inIRC R311.7.5.1
Top cutriser + tread − top finish7.95 inIRC R311.7.5.1
Checkbottom + 13 middle + top = rough6.95 + 13 × 7.2 + 7.95 = 108½ inarithmetic
Headroomframe above the finished limitframe 6 ft 10 in for 6 ft 8 inIRC R311.7.2 (6 ft 8 in finished)
FieldDojo field sheet, cut to framing: finished rise equals rough minus finish below plus above; this stair 108½ minus ¾ plus ¼ equals 108 in; layout 15 risers at 7.2 in; drop equals tread minus floor, 1 minus ¾ equals ¼ in; bottom cut 6.95 in; middle cuts 7.2 in; top cut 7.95 in; check 6.95 plus 13 times 7.2 plus 7.95 equals 108½; headroom frame 6 ft 10 in for 6 ft 8 in.
The stairs on subfloor: finished rise field sheet, free in the FieldDojo app to save or send. Same numbers as the table above.

Why rough rise is the wrong number

The inspector measures the stair you hand over, with the hardwood down and the treads on. The ⅜ in variation limit in IRC R311.7.5.1 applies to those finished risers. Lay the stair out from the rough rise, subfloor to subfloor, and the finishes land unevenly: the floor finish below shortens the first riser and the finish above lengthens the last one.

So start from the finished rise: the rough rise, minus the finish that will go down on the lower floor, plus the finish that will go down on the upper floor. On this stair: 108½ − ¾ + ¼ = 108 in, which lays out as 15 risers of 7.2 in.

The three cuts

The stringer sits on the subfloor, so the cuts are framing dimensions, not finished ones.

Check the arithmetic before you cut: 6.95 + 13 × 7.2 + 7.95 = 108½ in, the rough rise you measured. If the sum is off, a cut is wrong.

Headroom

6 ft 8 in is the finished number (IRC R311.7.2), measured plumb from the nosing line. Floor finish raises the nosing line and the ceiling finish lowers the ceiling, so frame the opening at 6 ft 10 in to land at 6 ft 8 in or better.

The layout itself comes from the stair rise and run chart, and the stair calculator runs it for any finished rise.

Code references

Section numbers and table values move between editions, and jurisdictions amend them. Confirm against the edition your authority having jurisdiction enforces.